11. PUMP Switch – OFF
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
12. Cab Control SYSTEM/POWER Switch – OFF
13. Vehicle – Wash or fresh water rinse areas exposed
to the foam spray.
TANK DRAIN
1. Cab Control SYSTEM/POWER Switch – ON
2. PUMP Switch – ON
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
3. DRAIN Switch – ON
4. Water Level – Drain to desired level.
Do not operate the water pump in a dry sump.
Dry running operation will cause water pump
failure.
Once operations are complete:
5. DRAIN Switch – OFF
6. PUMP Switch – OFF
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
7. Cab Control SYSTEM/POWER Switch – OFF
HOSE REEL
1. Hose Nozzle – CLOSED
2. Hose – Deploy desired length.
3. Gate Valve – OPEN
4. Cab Control SYSTEM/POWER Switch – ON
5. PUMP Switch – ON
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
6. Vehicle RPM – SET
7. Hose Nozzle – OPEN as desired.
Once operations are complete:
8. Hose Nozzle – CLOSE
9. Vehicle RPM – LOW IDLE
10. PUMP Switch – OFF
Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.
11. (If Equipped) Cab Control SYSTEM/POWER
Switch- OFF
12. Gate Valve – CLOSED
13. Hose – Reel in and stow hose nozzle.
WATER CIRCULATION SYSTEM
1. Fill water tank with appropriate fluid.
2. Start engine.
3. Cab Control SYSTEM/POWER Switch – ON.