beautypg.com

Typical installations, Standard installation, 45° skew” installation – Datalogic Scanning DS6400 User Manual

Page 51

background image

INSTALLATION

2

2.6 TYPICAL INSTALLATIONS

2.6.1 Standard

Installation


The DS6400 scanner is mounted on the ST-237 106° mounting bracket (see Figure 9) which
guarantees a built-in Skew angle (S in the figure below) of 16° with respect to the frame
plane (typically the Skew angle should be between 10° - 20°). This avoids the direct
reflection of the laser light emitted by the scanner. Furthermore, the bracket guides allow
adjusting the Tilt angle (T in the figure below, which is typically 0°) for the best scanner
orientation:

T

Conveyor Direction

S

Figure 48 – Standard Installation


2.6.2 “45° Skew” Installation


The DS6400 scanner is mounted on the ST-210 90° mounting bracket (see Figure 11). By
adjusting the mounting bracket guides, reach 45° for the Skew angle (S in the figure below)
to avoid the direct reflection of the laser light emitted by the scanner:

45°

S

Figure 49 – 45° Skew Installation

35