Technical features, 7 technical features – Datalogic Scanning DS6400 User Manual
Page 114
![background image](/manuals/77577/114/background.png)
DS6400
7
7 TECHNICAL
FEATURES
ELECTRICAL FEATURES
(see note 1)
Supply voltage
15 to 30 Vdc
Power consumption
15 W typical
20 W Max. (including startup current)
Main (isolated)
Baud Rate
RS232
1200 to 115200
RS485 full-duplex
1200 to 115200
RS485 half-duplex
1200 to 115200
20 mA current loop
(INT-30 with C-BOX 100 only)
19200
Auxiliary
RS232
1200 to 115200
Other
Lonworks 1.25
Mb/s
Ethernet
10 or 100 Mb/s
DeviceNet
125 or 250 Kb/s
Communication Interfaces
Profibus 12
Mb/s
Inputs
External Trigger 1,
3 auxiliary digital inputs
(optocoupled NPN or PNP)
Outputs (optocoupled),
3 software programmable digital
outputs
(optocoupled)
OPTICAL FEATURES
(see note 1)
Light receiver
Avalanche photodiode
Wavelength
630 to 680 nm
Safety class
Class 2 - EN60825-1; Class II - CDRH
Laser control
Security system to turn laser off in case of motor slow
down
READING FEATURES
Scan rate
600-1200 scans/s
Maximum resolution
Max. reading distance
Max. reading width
Max. depth of field
(see reading diagrams)
USER INTERFACE
LCD Display
2 lines by 16 characters LCD
Keypad 3
keys
LED indicators
Power ON (red)
Phase ON (yellow)
TX data (green)
Note 1: The features given are typical at 25 °C ambient temperature (if not otherwise indicated).