Datalogic Scanning DS6400 User Manual
Page 30
DS6400
2
The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this
pinout when the DS6400 reader is connected in a network by means of the
C-BOX 100:
C-BOX 100 Terminal Block Connectors
Power
1, 3, 5
VS
2, 4, 6
GND
7, 8
EARTH GROUND
20, 40
Reserved
Inputs
27
EXT TRIG/PS A (polarity insensitive) for PS
28
EXT TRIG/PS B (polarity insensitive) for PS
29
IN 2/ENC A (polarity insensitive) for Encoder
30
IN 2/ENC B (polarity insensitive) for Encoder
31, 33
IN 3A (polarity insensitive)
32, 34
IN 4A (polarity insensitive)
36
IN 3B/IN 4B Reference (polarity insensitive)
Outputs
21 OUT
1+
22 OUT
1-
23 OUT
2+
24 OUT
2-
25
OUT 3A (polarity insensitive)
26
OUT 3B (polarity insensitive)
Auxiliary Interface
35 TX
AUX
37 RX
AUX
38, 39
GND
Main Interface
Pin RS232
RS485
Full-Duplex
RS485
Half-Duplex
20 mA C.L.
(with
INT-30 only)
11, 15
TX232
TX485+
RTX485+
12, 16
RTS232
TX485-
RTX485-
17 RX232 *
RX485+
18 CTS232 *
RX485-
10, 14, 19
SGND Main Isolated SGND Main Isolated
SGND Main Isolated
9, 13
RS485 Cable Shield RS485 Cable Shield
see INT-30
instructions
* Do not leave floating, see par. "RS485 Full-Duplex Interface" for connection details.
14