Pull forwards the hobtop to release it, then lift following arrow “E” (fig. 31 and 32).
[
Hold the hobtop open by a support.
[
Fully raise the adjusting air tube “A” (fig. 33) in order to easily reach the injector.
[
Using a 7mm A/F angled spanner, remove the injector from its housing and replace it
with one suitable the kind of gas supplied(see following tables - pag.35).
[
Affix to the rear of the appliance, in proximity of the gas inlet connection, the warning
label (supplied with the conversion kit) stating that the cooker has been converted for
use with LPG-Propane / Natural Gas.
IMPORTANT
[
If the cooker is suitable for use with Natural Gas and must be converted for use with
LPG-Propane, before connecting to gas main remove the appliance gas regulator and
replace with test point adaptor (see figs. 30a - 30b).
[
If the cooker is suitable for use with LPG-Propane and must be converted for use with
Natural gas, before connecting to gas main remove the appliance test point adaptor
and replace with gas regulator (see figs. 30a - 30b).
NOTE:
Gas regulator and test point adaptor are supplied with the appliance (packed with
conversion kit).
Fig. 32
A
B
E
D
D
E