Adjustment of the pre-gas and post-gas times, Adjustment of the form of the arc, balance – Kemppi DC 2000 User Manual

Page 17

background image

Mastertig aC/DC 000, 500, 500W, 3500W/0701 – 17

© keMppi oy

2

2

15 s

coDe lock

2

2

5

1 3

4

4-function (4T) / contact ignition

1. Press the electrode lightly against the work piece.
2. Press the torch switch down for a moment.
3. Lift the electrode slowly away from the work piece. The

arc will ignite and the welding current will rise to the

welding level within the up-slope time.

4. Press the torch switch down. The welding continues.
5. Release the torch switch, and the welding current will

drop and stop after the selected down-slope time. After

the arc is turned off, the shielding gas will continue to

flow for the post-gas time.

By pressing the torch switch during the down-slope time of the current, the

current will remain at that level as long as the switch is pressed down. After

the release of the switch, the current will drop further.
By pressing the switch down for a moment, you can raise the welding

current back to the welding level.

3.4.5. Adjustment of the down-slope time of the welding current

The adjustment of the down-slope time is done from the poten-

tiometer. The time can be adjusted between 0 - 15 s. When you

adjust the down-slope time, you can see the time in seconds in

the right-hand numerical display. After 5 seconds, the display

will return to the start status.

3.4.6. Adjustment of the up-slope time of the welding current

1. Press the key next to the up-slope of the current pattern.

The right-hand numerical display will show the up-slope

time in seconds.

2. Select the desired value by turning the current knob

(0 - 5 s). 5 seconds after the adjustment, the displays will

return to show the set value of the current.

3.4.7. Adjustment of the pre-gas and post-gas times

1. Press the switch in the panel next to the gas bottle of the current model of either the pre-gas

or the post-gas.

2. Turn the current knob until the value that you want is shown in the right-hand display. (Pre-

gas 0 - 5 s, post-gas 3 - 100 s)

3.4.8. Adjustment of the form of the arc, BALANCE

The BALANCE function will adjust the balance so that it is suitable for the selected electrode

and current. At the same time, it adjusts the pre-heating of the tip of the electrode at the start

in accordance with the tip form selected.