beautypg.com

Numerical displays and signal lights of the panel, 2 use of the remote control, Mma welding – Kemppi DC 2000 User Manual

Page 14

background image

1 – Mastertig aC/DC 000, 500, 500W, 3500W/0701

© keMppi oy

3.1. nuMerical Displays anD signal lights of the panel

Machine on

Heat protection

Wrong mains voltage, over or under-voltage

Display of

welding current

or set value

current

Display of

welding voltage

or parameters

Units of the display

The signal light of thermal protection is on when the machine has over-heated. Let the machine on so

that the fan will cool the machine. Wait until the light goes off, and you can continue welding.
The light for the wrong voltage turns on if the mains voltage is too high or too low. Check the voltage

setting of the machine and/or the mains voltage. The wrong voltage light will also turn on if there is a

momentaneous over-voltage in the mains supply.
The current is displayed with a tolerance of 3 % ± 2 A; the voltage with a tolerance of 3 % ± 0.2 V.

3.2 use of the reMote control

The remote control is selected from the key REMOTE. With

the remote control you can adjust the welding current of MMA

and TIG welding. The values of the parameters (up-slope and

down-slope times, gas flow times etc.) are adjusted from the

current knob.
With remote control unit C 100AC you can also change the

welding method (MMA / TIG). The machine selects the polarity

(type of current) in accordance with an advance selection on

the panel.

3.3. MMa WelDing

3.3.1. Selection of type of current

Select MMA welding by pressing the selection key of MMA welding. The signal light of the

type of current indicates the current type selected: AC, DC-, DC+.
Change the current type by pressing the MMA selection key again and the current type will

change and the signal light will show the current type selected.

3.3.2. Broken arc method

Press the BROKEN ARC key and the signal light for broken arc method turns on.
A broken arc method has to be used if the seam to be welded cannot tolerate the heat of a

continuous arc. The heat of the welding is controlled by breaking the arc. Usually the reason is

thin material or various fittings. In the broken arc method position, the arc breaks faster and the

ignition pulse is smaller then in ordinary MMA welding.