beautypg.com

Electrical characteristics curves – Delta Electronics H48SR User Manual

Page 5

background image

DS_H48SR1R880_06272006

ELECTRICAL CHARACTERISTICS CURVES

Figure 9:

Turn-on transient at zero load current (2 ms/div).

Top Trace: Vout: 1V/div; Bottom Trace: ON/OFF input:
2V/div

Figure

10:

Output voltage response to step-change in load

current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap:
10µF, tantalum capacitor and 1µF ceramic capacitor. Top Trace:
Vout (20 mV/div), Bottom Trace: Iout (20A/div). Scope
measurement should be made using a BNC cable (length shorter
than 20 inches). Position the load between 51 mm to 76 mm (2
inches to 3 inches) from the module..

Figure 11:

Output voltage response to step-change in load

current (75%-50%-75% of Io, max: di/dt = 2.5A/µs). Load
cap: 470µF, 35m

 ESR solid electrolytic capacitor and 1µF

ceramic capacitor. Top Trace: Vout (100mV/div), Bottom
Trace: Iout (20A/div). Scope measurement should be made
using a BNC cable (length shorter than 20 inches). Position
the load between 51 mm to 76 mm (2 inches to 3 inches)
from the module.

Figure

12:

Test set-up diagram showing measurement points for

Input Terminal Ripple Current and Input Reflected Ripple Current.
Note: Measured input reflected-ripple current with a simulated
source Inductance (L

TEST

) of 12 µH. Capacitor Cs offset possible

battery impedance. Measure current as shown above.

5