40
USB hardware delay and time-outs:
USB Transfer time-out
Use this item to set the time-out value for control, bulk, and interrupt transfers.
The optional settings are: [1 sec]; [5 sec]; [10 sec]; [20 sec].
Device reset time-out
Use this item to set USB mass storage device start unit command time-out.
The optional settings are: [10 sec]; [20 sec]; [30 sec]; [40 sec].
Device power-up delay
Use this item to set maximum time the device will take before it properly reports
itself to the host controller. ‘Auto’ uses default value: for a root port it is 100 ms, for
a hub port the delay is taken from hub descriptor.
Select [Manual] you can set value for the following sub-item: ‘Device Power-up
delay in seconds’.
Device Power-up delay in seconds
The delay range is from 1 to 40 seconds, in one second increments.
Intel(R) Ethernet Connection I218-LM-XX:XX:XX:XX:XX:XX/ Intel(R) I211
Gigabit Network Connection- XX:XX:XX:XX:XX:XX
Press [Enter] to view current network information and make further settings in ‘NIC
Configuration’
NIC Configuration
Press [Enter] to configure the network device port.
Link Speed
Use this item to specify the port speed used for the selected boot protocol.
The optional settings are: [Auto Negotiated]; [10 Mbps Half]; [10 Mbps Full]; [10
0Mbps Half]; [100 Mbps Full].
Wake On LAN
Use this item to enable the server to be powered on using an in-hand magic
packet.
Blink LEDs
Use this item to identify the physical network port by blinking the associated LED.