– Do not mix more than 400 g investment material at the same time.
– Strictly observe mixing ratios.
– Check the function of the vacuum mixing device on a regular basis.
– Do not place the invested ring in a pressure vessel during the setting phase. This procedure changes
the physical properties of the investment material.
– Do not leave the investment over the weekend (risk of cracks and flash).
– Always remove pressed rings from the press furnace immediately after the end of the program. Place
the ring on a grid and let it cool.
– To achieve sufficient heating of the rings in the preheating furnace, the following instructions have to be
observed:
– Use max. 50% of the available space in the preheating furnace.
– Always place the rings in the rear part of the firing chamber.
– Always place set invested rings in the burnout furnace with the opening facing downward, preferably
at a 45° angle.
– The investment rings must not touch each other. Permit air circulation.
– When divesting the object, make sure that you remove only excess investment material during preblasting
at 4 bar pressure. Be careful not to blast the ceramic object at this pressure.
Saftey Warnings
Warning: The investment material contains quartz powder. Inhalation of dust should be avoided.
(Prolonged exposure to dust may cause lung damage and silicosis).
Physical data according to – Compressive strength
mind. 2.5 N/mm
2
– liquid concentration 50 %
ISO 9694 – 1998
– Fluidity
17–21 cm – liquid concentration 50 %
– Setting time
7–13 minutes – liquid concentration 50 %
– Linear thermal expansion
1.35–1.65 % – liquid concentration 50 %
This material has been developed solely for use in dentistry. Processing should be carried out strictly according to the Instructions for Use. Liability cannot be accepted for damage resulting from