Final polymerization, Finishing / polishing – Ivoclar Vivadent SR Nexco Paste User Manual
Page 54

54
fInaL PoLymErIzatIon
to minimize the inhibition layer, apply a covering but not too thick layer of Sr Gel prior to polyermization in a
Lumamat 100. then conduct the final polymerization in a Lumamat 100. the final processing of Sr nexco Gingiva is
limited to minor shape corrections and polishing of the surface.
fInISHInG / PoLISHInG
Finishing
after completion of the polymerization procedure, completely remove Sr Gel from the restoration using running water.
Use regular tungsten carbide burs and polishers to design and finish the surface and the surface texture. the inhibition
layer must be removed from the entire Sr nexco surface.
Finish with cross-cut tungsten carbide burs and stippling instruments.
Subsequently, polish with Universal Polishing Paste.
Apply a covering but not inappropriately thick coat of SR Gel and conduct the final polymerization.
Final polymerization
Appliance
Time
Program
Precuring time per segment
Quick
20 s
–
final polymerization
Lumamat 100
11 min
P2
For the parameters of other polymerization devices, please go to page 57.