English – Ivoclar Vivadent SR Ivolen User Manual
Page 3
English
Instructions for Use
Product Description
The cold-curing SR Ivolen is especially suitable for the
fabrication of individualized trays, base plates and
registration base plates.
In conjunction with the corresponding adhesive, SR Ivolen
can be used with most impression materials.
Colour
yellow
Composition
Powder
Polymethyl methacrylate, copolymer, calcium carbonate,
catalyst and pigment
Liquid
Methyl methacrylate and paraffin oil, catalyst
Indication
–
Personalized impression trays
–
Individualized base plates for:
– wax rims
– intra-oral registration devices (e.g. Gnathometer M)
– Tooth setup with wax
– Fabrication of incisal plates for personalized anterior
guidance (e.g. in Stratos
®
)
Contraindication
–
Material must not be processed in the oral cavity.
–
Material is unsuitable for alginates and hydrocolloids.
–
If the patient is known to be allergic to any of the
ingredients in SR Ivolen.
Application
After blocking out undercuts, soak the cast and isolate
with Ivoclar Vivadent Separating Fluid.
Mix the polymer (powder) and monomer (liquid)
according to the Instructions: 1 measuring spoon of
SR Ivolen polymer to 6 ml of SR Ivolen monomer. Mix in
a mixing cup and spatulate well until the dough no
longer sticks to the mixing cup. Knead the dough for a
few more seconds. Wear gloves for kneading.
SR Ivolen can be immediately applied and shaped; the
material is not sticky. Alternatively, the material can be
pressed between 2 polyethylene sheets with a
compression roller to form a layer of uniform thickness.
Adapt SR Ivolen to the cast; shape with a suitable
instrument and cut off excess.
4
3
2
1
You may use excess to form tray handles.
After the material has self-cured for approx. 7 minutes,
trim the margins with burs or similar instruments. If
desired, you may also polish SR Ivolen.
Warnings
–
The monomer contains methyl methacrylate (MMA)
–
MMA is irritating and easily flammable (flash point:
+10 °C/50 °F)
–
MMA is irritating to the eyes, skin and respiratory
system
–
May cause sensitization upon skin contact
–
Avoid contact of the skin with monomer or uncured
material. Commercial medical gloves do not provide
protection against the sensitizing effect of
methacrylates.
–
Do not inhale vapours
–
Keep away from sources of ignition – no smoking.
–
Do not empty into drains.
–
Take precautionary measures against static discharges
Storage
–
Storage temperature: 2–28 °C / 36–82 °F. Protect
material from light.
–
Do not use material after the indicated date of
expiration.
–
Keep out of the reach of children.
Date information prepared: 11/2010
Manufacturer:
Ivoclar Vivadent AG, FL-9494 Schaan / Liechtenstein
The material has been developed solely for use in dentistry. Processing should be carried
out according to the Instructions for Use. Liability cannot be accepted for damages resulting
from failure to observe the Instructions or the stipulated area of application. The user is
responsible for testing the material for its suitability and use for any purpose not explicitly
stated in the Instructions. Descriptions constitute no warranty of attributes.
6
5