5. Operation and configuration
5.1 Introduction to the operation
The	Programat	CS	is	equipped	with	a	graphical	display	with	back-
lighting.	By	means	of	the	enter	keys	and	the	command	keys	(B),	the	
furnace	may	be	programmed	and	controlled.
5.2 Explanation of key functions
– Settings key (78) 
	 After	pressing	the	‚Settings‘	key,	the	settings	of	the	furnace	can	
be displayed and/or changed one after the other.
– Information key (81)
	 After	pressing	the	‚Information‘	key,	the	information	about	the	
furnace can be displayed one after the other.
– Cursor keys (79, 80)
	 By	pressing	the	cursor	keys	in	the	stand-by	mode,	the	program	
can be changed.
The cursor keys can be used to browse through the settings and/
or	information.	In	the	list	of	parameters,	the	current	cursor	posi-
tion	is	indicated	by	an	illuminated	(non-blinking)	frame	around	the	
numerical	value.
– – / + keys (76, 77)
	 Changing	the	settings	or	entry	of	a	numerical	value	are	carried	
out	using	the	–/+	keys.	Each	individual	entry	by	means	of	the	‚–‘	
or	‚+‘	key	is	immediately	accepted,	provided	the	corresponding	
value	range	is	observed.	Once	the	limit	of	the	value	range	is		
reached,	the	value	is	no	longer	adjusted.
– ESC key (71)
	 This	key	is	used	to	close	an	error	indication.	Moreover,	any	screen	
can be left by pressing this key.
– ENTER key (72)
	 This	key	is	used	to	select	settings	or	confirm	entries.
– START key (73)
	 Pressing	this	key	starts	the	selected	program.	Starting	a	program	is	
only possible with the furnace head open.
– Start LED (74)
	 Illuminated	if	a	program	has	been	started.	The	LED	is	blinking		
while a program is paused.
– STOP key (75)
	 Pressing	this	key	once	(program	paused)
	 Pressing	this	key	twice	(program	will	be	interrupted	and	vacuum	
flooded).	With	the	STOP	key	the	movement	of	furnace	head	and	
the	beeper	will	be	interrupted,	too.
 – Open furnace head key (87)
	 The	furnace	head	is	opened	(not	possible	during	a	program	in		
progress).
– Close furnace head key (88)
	 The	furnace	head	is	closed	(not	possible	during	a	program	in		
progress).
– Program 1 key (82)
	 Used	to	select	Program	1	(P1)	(not	possible	during	a	program	in	
progress).
– Program 2 key (83)
	 Used	to	select	Program	2	(P2)	(not	possible	during	a	program	in	
progress).
– Program 3 key (84)
	 Used	to	select	Program	3	(P3)	(not	possible	during	a	program	in	
progress).
– Program 4 key (85)
	 Used	to	select	Program	4	(P4)	(not	possible	during	a	program	in	
progress).
– Next program key (86)
	 Used	to	select	the	next	program	(P5,	P6,	…)	(not	possible	during	a	
program in progress).
5.3 Basic meaning of the display information
– Stand-by mode
– Firing curve display
	
Status area
Recommendation	
area
The	most	likely	action	to	
follow	is	indicated		
(keystroke).
Furnace	and/or	
program	status
Current	temperature	
of	the	furnace
Main area
In	the	main	area,	the	most	
important	information	
(e.g.	the	currently	selected	
program)	is	shown.
Status area
Status bar
Remaining time
Furnace	and/or	
program	status
Current	temperature	
of	the	furnace
Main area
Currently	selected		
program
78
81
79
80
77
82
83
84
85
86
72 71
76
B
87
88
75
73
74