Product description – Ivoclar Vivadent CS User Manual
Page 12
12
3. Product Description
3.1 Components
The Programat CS comprises the
following components:
– Furnace base with electronic
controls
– Furnace head with firing
chamber
– Firing table
– Cooling tray
– Power cord and hose for
vacuum pump
– Vacuum pump (accessory)
3.2 Hazardous areas and safety equipment
Description of the risk areas of the furnace:
3.3 Functional description
The firing chamber may be heated up to max. 1200 °C (2192 °F) by
means of a heating element. Furthermore, the firing chamber has
been designed in such a way that a vacuum may be created with a
vacuum pump. The firing process is controlled with the
corresponding electronic controls and a software. Moreover,
the set and actual temperatures are continuously compared.
3.4 Accessories
(not part of the delivery form)
– Automatic Temperature Checking Set 2 (ATK 2)
– Programat Accessories Set (large and small firing trays, firing
tongs, Temperature Checking Set)
– Vacuum pump
3.5 Indication/Contraindication
Indication
– Glaze and crystallization firings (chairside area)
Contraindication
– The Programat CS is not suitable as ceramic furnace for dental
laboratories
Description of the safety equipment of the furnace:
Safety equipment
Protective effect
Protective conductor
Protection from electrical shock
Electrical fuses
Protection from electrical shock
Hazardous area
Type of risk
Firing chamber
Risk of burning
Opening/closing mechanism
Risk of crushing
Electrical components
Risk of electrical shock