B = Stand-by temperature °C / °F

S =Closing time/min.

t = Temperature increase rate °C/min.

T = Firing temperature °C / °F

H = Holding time/min.

V

1

= Vacuum-on temperature °C / °F

V

2

= Vacuum-off temperature °C / °F

IPS Empress CAD stained with IPS Empress Universal

IPS Empress CAD with IPS Empress Universal
2-in-1 technique

B

°C / °F

S

min.

t

°C/min. / °F/min.

T

°C / °F

H

min.

V

1

°C / °F

V

2

°C / °F

Stain and glaze firing

403

6:00

100

790

1:00 – 2:00

Corrective firing
IPS Empress Add-On 770 °C / 1418 °F

403

04:00

60

770

02:00

450

769

IPS Empress CAD with
IPS Empress Universal

B

°C / °F

S

min.

t

°C/min. / °F/min.

T

°C / °F

H

min.

V

1

°C / °F

V

2

°C / °F

Stain and glaze firing

403

6:00

100

790

01:00

Glaze firing

403

06:00

100

790

1:00 – 2:00

Corrective firing
IPS Empress Add-On 770 °C / 1418 °F

403

04:00

60

770

02:00

450

769

IPS Empress CAD veneered with IPS Empress Esthetic Veneer

IPS Empress CAD with
IPS Empress Esthetic Veneer
Cut-back and veneered

B

°C / °F

S

min.

t

°C/min. / °F/min.

T

°C / °F

H

min.

V

1

°C / °F

V

2

°C / °F

Wash firing

403

04:00

60

840

02:00

450

839

1. Incisal / Transpa firing

403

04:00

60

830

02:00

450

829

2. Incisal / Transpa firing

403

04:00

60

830

02:00

450

829

Stain and characterization firing

403

06:00

100

790

01:00

450

789

Glaze firing

403

6:00

100

790

1:00 – 2:00

450

789

Corrective firing
IPS Empress Add-On 770 °C / 1418 °F

403

04:00

60

770

02:00

450

769