Ivoclar Vivadent PS Empress CAD Chairside User Manual
Page 34

34
B = Stand-by temperature °C / °F
S =Closing time/min.
t = Temperature increase rate °C/min.
T = Firing temperature °C / °F
H = Holding time/min.
V
1
= Vacuum-on temperature °C / °F
V
2
= Vacuum-off temperature °C / °F
IPS Empress CAD stained with IPS Empress Universal
IPS Empress CAD with IPS Empress Universal
2-in-1 technique
B
°C / °F
S
min.
t
°C/min. / °F/min.
T
°C / °F
H
min.
V
1
°C / °F
V
2
°C / °F
Stain and glaze firing
403
6:00
100
790
1:00 – 2:00
–
–
Corrective firing
IPS Empress Add-On 770 °C / 1418 °F
403
04:00
60
770
02:00
450
769
IPS Empress CAD with
IPS Empress Universal
B
°C / °F
S
min.
t
°C/min. / °F/min.
T
°C / °F
H
min.
V
1
°C / °F
V
2
°C / °F
Stain and glaze firing
403
6:00
100
790
01:00
–
–
Glaze firing
403
06:00
100
790
1:00 – 2:00
–
–
Corrective firing
IPS Empress Add-On 770 °C / 1418 °F
403
04:00
60
770
02:00
450
769
IPS Empress CAD veneered with IPS Empress Esthetic Veneer
IPS Empress CAD with
IPS Empress Esthetic Veneer
Cut-back and veneered
B
°C / °F
S
min.
t
°C/min. / °F/min.
T
°C / °F
H
min.
V
1
°C / °F
V
2
°C / °F
Wash firing
403
04:00
60
840
02:00
450
839
1. Incisal / Transpa firing
403
04:00
60
830
02:00
450
829
2. Incisal / Transpa firing
403
04:00
60
830
02:00
450
829
Stain and characterization firing
403
06:00
100
790
01:00
450
789
Glaze firing
403
6:00
100
790
1:00 – 2:00
450
789
Corrective firing
IPS Empress Add-On 770 °C / 1418 °F
403
04:00
60
770
02:00
450
769