In order to individualize restorations in the incisal area so that they correspond with their natural model, the
IPS Empress CAD restoration is additionally veneered using opalescent IPS Empress Esthetic Veneer ceramic
materials.
The cut-back technique is very efficient if the full-contour anterior crown or the veneer is first designed
according to the definite final shape. After that, the incisal third is reduced and subsequently provided with
an individualized esthetic veneer.
For a detailed description of the materials used and the individual working steps, please refer to the
Instructions for Use of IPS Empress CAD labside.
Empress
®
CAD
Veneers / Anterior Crowns –
cut-back and layered
IPS
Instructions for Use
labsid
e
Empress
®
CAD
IPS
Empress
®
System
IPS
After the CAM process, the fitted IPS Empress CAD
restoration is partially reduced using suitable grinding
instruments. Excess pressure and overheating is
prevented. No extreme mamelon structures are milled.
The wash firing is performed using the IPS Empress
Esthetic Veneer Wash Pastes.
The anatomical shape of the reduced areas is
completed using IPS Empress Esthetic Veneer materials.