English – Ivoclar Vivadent IPS PressVEST Speed User Manual
Page 3
3
IPS e.max
®
ZirPress
Indication
Concentration
approx.
100-g investment
ring
Liquid : dist. water
200-g investment
ring
Liquid : dist. water
300-g investment
ring
Liquid : dist. water
Pressing over ZrO
2
single
tooth constructions
60%
16 ml : 11 ml
32 ml : 22 ml
48 ml : 33 ml
Pressing over ZrO
2
frameworks
bridge constructions
50%-60%
---
27 ml : 27 ml
48 ml : 33 ml
IPS Empress
®
Cosmo
Indication
Concentration
approx.
100-g investment
ring
Liquid : dist. water
200-g investment
ring
Liquid : dist. water
300-g investment
ring
Liquid : dist. water
Preprosthetic buildup in
combination with CosmoPost
40%-50%
11 ml : 16 ml
13.5 ml : 13.5 ml
22 ml : 32 ml
27 ml : 27 ml
---
IPS InLine
®
Pom – Press-on-metal ceramic
Indication
Concentration
approx.
100-g investment
ring
Liquid : dist. water
200-g investment
ring
Liquid : dist. water
300-g investment
ring
Liquid : dist. water
Pressing over opaquerized
metal frameworks
60%
16 ml : 11 ml
32 ml : 22 ml
48 ml : 33 ml
The total quantity of liquid (liquid + dist. water) must not be altered. The indications regarding the liquid
concen tration are approximates and may be adjusted, if required. Do not dilute the liquid to below 40%.
Processing
Excess of separating agents may cause reactions with the investment material and affect the press result.
Disperse excess with compressed air before investment.
– Fill liquid into the mixing cup.
– Add powder.
– Thoroughly mix the investment material with a spatula for 20 seconds until even wetting of the powder is
achieved.
Vacuum mixer
Vacuum mixing time (at room temperature)
2.5 min
Speed
approx. 350 rpm
Processing time
6 – 7 min
Setting time
min. 30 min – max. 45 min
The processing time depends on the material temperature, mixing quantity, mixing time and mixing intensity.
A higher material temperature and/or longer mixing time shortens the processing time.
Investment
– Mix max. 400 g of investment material in one go
– Closely observe the mixing ratio!
– Investment is carried out on a shaker under slight vibration. Allow the investment ring to set without
manipulating it.
Some aspects influencing the setting expansion of the investment material
– Temperature of the investment material and the liquid
– Residual water in the mixing cup, atmospheric humidity