beautypg.com

Factory reset, Remote control – ikan KVM-2450W User Manual

Page 29

background image

Shenzhen Konvision Technology Co,.Ltd www.konvision.com

29

● Factory Reset

This function is to reset the monitor to factory preset.

Please try to reset the monitor, when the following situations occur:

1. The monitor parameters are adjusted incorrect by user.

2. The monitor picture or sound is abnormal, and not due to hardware problem.

To do factory reset, please follow the below five steps:

1. Press MENU button to enter main menu.

2. Turn VOLUME knob to item Setup and select it.

3. Turn IMAGE ADJ knob to Factory Reset and select it.

4. The screen will refresh after following the instruction of turning the VOLUME knob.

5. Power off the monitor, and must wait for at least 5 seconds, then restart the monitor.

The monitor resets to factory preset.

● Remote Control

1. Hardware connection

Connect the monitor’s RS-232 serial port to the computer to remote control the

monitor by universal serial communication software.

2. Software Configuration

Start communication software, configure the serial communication parameters,

sending communications test command, if the return value is correct, you can send

control command.

Serial port settings:

 

Baud Rate: 19200

Parity: None

 

 

 

Data bits: 8

Stop bit: 1

 

 

Flow Control: None