Test 2 – power board voltage checks, Test 2 – power board voltage checks -19, Test 2 – power – Hypertherm Powermax45 Service Manual User Manual
Page 95: Board voltage checks, Powermax
TroubleshooTing and sysTem TesTs
powermax
45
Service Manual
5-19
Single phase
Three phase (Ce)
Three phase (CSA)
L
Black (CSA)
Brown (CE)
L1
Brown
L1
Black
N
White (CSA)
Blue (CE)
L2
Black
L2
White
PE
Green (CSA)
Green/yellow (CE)
L3
Gray
L3
Red
PE
Green/yellow
PE
Green
Test 2 – power board voltage checks
With the power ON, use a meter to verify the voltages at the J7 pins (J8 on 400 V CE and 480 V CSA power supplies)
listed in the following table to be certain that the power board is functioning correctly. If any of the values are incorrect,
replace the power board.
CAUTIoN
do not use -VbUS as ground – doing so could destroy the power supply. Instead ground to either the
ground wire clip on the rear panel or to the heat sink as shown below.
Note: All values can be ±10%.
J7 or J8 pin number to
ground
Test
expected value
(200–240 V CSA or
230 V Ce)
expected value
(400 V Ce or 480 V CSA)
19
VACR (rectified AC
line voltage)
1.95 V at 230 line
voltage
2.7 V at 400 line voltage (CE)
2.016 VDC at 480 line voltage (CSA)
21
VBUS (DC bus
voltage)
2.28 VDC at 385 VBUS 2.178 VDC at 560 VBUS (CE)
2.016 VDC at 670 VBUS (CSA)
18
(200–240 and 230 V
only)
IPFC (input current)
< 0.1 VDC
Not applicable
20
IFB (output current)
< 0.1 VDC
< 0.1 VDC
22
ITF (transfer current) < 0.1 VDC
< 0.1 VDC
25
3.3 VDC
3.3 VDC ±5%
3.3 VDC ±5%
24
5 VDC
5 VDC ±5%
5 VDC ±5%
12
24 V sense pin
2.2 VDC
2.2 VDC
16
Start signal
3.2 VDC closed
0 VDC open
3.2 VDC closed
0 VDC open