beautypg.com

Test 2 – power board voltage checks, Test 2 – power board voltage checks -19, Test 2 – power – Hypertherm Powermax45 Service Manual User Manual

Page 95: Board voltage checks, Powermax

background image

TroubleshooTing and sysTem TesTs

powermax

45

Service Manual

5-19

Single phase

Three phase (Ce)

Three phase (CSA)

L

Black (CSA)

Brown (CE)

L1

Brown

L1

Black

N

White (CSA)

Blue (CE)

L2

Black

L2

White

PE

Green (CSA)

Green/yellow (CE)

L3

Gray

L3

Red

PE

Green/yellow

PE

Green

Test 2 – power board voltage checks

With the power ON, use a meter to verify the voltages at the J7 pins (J8 on 400 V CE and 480 V CSA power supplies)

listed in the following table to be certain that the power board is functioning correctly. If any of the values are incorrect,

replace the power board.

CAUTIoN

do not use -VbUS as ground – doing so could destroy the power supply. Instead ground to either the

ground wire clip on the rear panel or to the heat sink as shown below.

Note: All values can be ±10%.

J7 or J8 pin number to

ground

Test

expected value

(200–240 V CSA or

230 V Ce)

expected value

(400 V Ce or 480 V CSA)

19

VACR (rectified AC

line voltage)

1.95 V at 230 line

voltage

2.7 V at 400 line voltage (CE)

2.016 VDC at 480 line voltage (CSA)

21

VBUS (DC bus

voltage)

2.28 VDC at 385 VBUS 2.178 VDC at 560 VBUS (CE)

2.016 VDC at 670 VBUS (CSA)

18

(200–240 and 230 V

only)

IPFC (input current)

< 0.1 VDC

Not applicable

20

IFB (output current)

< 0.1 VDC

< 0.1 VDC

22

ITF (transfer current) < 0.1 VDC

< 0.1 VDC

25

3.3 VDC

3.3 VDC ±5%

3.3 VDC ±5%

24

5 VDC

5 VDC ±5%

5 VDC ±5%

12

24 V sense pin

2.2 VDC

2.2 VDC

16

Start signal

3.2 VDC closed

0 VDC open

3.2 VDC closed

0 VDC open