beautypg.com

Control board leds, Control board leds -16, Control board leds on – Hypertherm Powermax45 Service Manual User Manual

Page 92: Powermax

background image

TroubleshooTing and sysTem TesTs

5-16

powermax

45

Service Manual

Control board leds

The Powermax45 control board (PCB1) has 4 diagnostic LEDs.

The control board LEDs are:

• Start – The power supply has a start signal. This LED illuminates when the power supply receives a start signal and

remains illuminated during normal operation.

• Transfer – This LED illuminates when there is proper arc transfer between the torch and the workpiece, and will flash

during continuous pilot arc operation (such as when cutting expanded metal or moving the arc off the plate

and then back on).

• Error – The Error LED illuminates whenever there is a fault in the system. If the Fault LED on the front panel flashes

and the Error LED on the control board also flashes, there is a major fault in the system. The number of

flashes between pauses indicates which component may have failed.

• Reset – This LED illuminates when the reset circuit is active or the watchdog circuit fires.
During normal operation, the power ON LED on the front of the power supply and the Start and Transfer LEDs on the

control board illuminate. When a problem occurs with the system, one or more of the LEDs on the front of the power

supply and the Error LED or the Reset LED on the control board may illuminate or flash.

Control board

Ribbon cable

Reset/watchdog

Error

Transfer (XFR)

Start