TroubleshooTing and sysTem TesTs
powermax
45
Service Manual
5-3
480 V CSA 3-phase power supply functional description
AC power enters the system through the power switch (S1) to the input diode bridge (D48). The voltage from the
diode bridge supplies the power factor correction (PFC) choke, which provides a nominal 670 VDC bus voltage. The
bus voltage then supplies voltage and current to the inverter and the flyback circuit power supply (DC to DC converter)
on the power board (PCB2). The power board provides noise suppression and spike protection. A “soft start” is
implemented via the power board resistor and relays (K2).
The inverter consists of a dual IGBT package (Q2), the power transformer, a current sense transducer, and the control
circuit. The inverter operates as a pulse-width modulated half-bridge circuit driving an isolation transformer. The
secondary of the isolation transformer is rectified by the output bridge (D40).
The output circuitry consists of 2 current sense transducers located on the power board, the pilot arc IGBT (inside the
D40 module), and the output choke.
The control board’s digital signal processor (DSP) monitors and regulates the system’s operation and safety circuits.
The amperage adjustment knob is used to set the output current to the desired value between 20 and 45 amps. The
system compares the set-point to the output current by monitoring the current sense transducers and adjusting the
pulse-width output of the inverter IGBT (Q2).