beautypg.com

Control board diagram: 200–240 v csa and 230 v ce, Powermax, Wiring diagrams 8-2 – Hypertherm Powermax45 Service Manual User Manual

Page 144: Service manual, Control pwa, Machine front

background image

Wiring Diagrams

8-2

powermax

45

Service Manual

FAULT

YEL

AMPS

CW

CAPOFF

YEL

"TSO/TSC"

AC PWR

GRN

"L/H LINE"

720

IN

15

IN

9

V-

8

IN

7

IN

13

IN

12

IN

11

IN

10

IN

6

V+

16

IN

3

IN

2

IN

1

IN

5

IN

14

IN

4

JTAG

1

3

5

7

9

11

13

14

2

4

6

8

10

12

1

2

3

4

5

6

7

8

9 10

11 12

13 14

15 16

17 18

19 20

21 22

23 24

25 26

2

1

3

4

56

7

ON

ON CASE

CASE

1

2

3

4

TEMP

YEL

L

R

1

ERROR
CODE

.25"
FOR
BD
DEPAN-
IZATION

SERIAL
DATA

MACHINE

FRONT

DSP 2806
4x25Mhz=100Mhz
0.78 x 0.78"
Stayout for

TEST CLIP

/RESET or
HDR FLT

START

XFR

GAS

CONTROL PWA

CPA (UP)

NORMAL (MIDDLE)

GOUGE (DOWN)

YEL

YEL

GRN

"SETPOINT"

GRN

GRN

MODE

45 A 230 V

Control board diagram: 200–240 V CSA and 230 V Ce

J7 pin number to ground

Test

expected value

(200–240 V CSA or 230 V Ce)

19

VACR (rectified AC line

voltage)

1.95 V at 230 line voltage

21

VBUS (DC bus voltage)

2.28 VDC at 385 VBUS

18

(200–240 and 230 V only)

IPFC (input current)

< 0.1 VDC

20

IFB (output current)

< 0.1 VDC

22

ITF (transfer current)

< 0.1 VDC

25

3.3 VDC

3.3 VDC ±5%

24

5 VDC

5 VDC ±5%

12

24 V sense pin

2.2 VDC

16

Start signal

3.2 VDC closed
0 VDC open

This manual is related to the following products: