Control board diagram: 200–240 v csa and 230 v ce, Powermax, Wiring diagrams 8-2 – Hypertherm Powermax45 Service Manual User Manual
Page 144: Service manual, Control pwa, Machine front
Wiring Diagrams
8-2
powermax
45
Service Manual
FAULT
YEL
AMPS
CW
CAPOFF
YEL
"TSO/TSC"
AC PWR
GRN
"L/H LINE"
720
IN
15
IN
9
V-
8
IN
7
IN
13
IN
12
IN
11
IN
10
IN
6
V+
16
IN
3
IN
2
IN
1
IN
5
IN
14
IN
4
JTAG
1
3
5
7
9
11
13
14
2
4
6
8
10
12
1
2
3
4
5
6
7
8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
2
1
3
4
56
7
ON
ON CASE
CASE
1
2
3
4
TEMP
YEL
L
R
1
ERROR
CODE
.25"
FOR
BD
DEPAN-
IZATION
SERIAL
DATA
MACHINE
FRONT
DSP 2806
4x25Mhz=100Mhz
0.78 x 0.78"
Stayout for
TEST CLIP
/RESET or
HDR FLT
START
XFR
GAS
CONTROL PWA
CPA (UP)
NORMAL (MIDDLE)
GOUGE (DOWN)
YEL
YEL
GRN
"SETPOINT"
GRN
GRN
MODE
45 A 230 V
Control board diagram: 200–240 V CSA and 230 V Ce
J7 pin number to ground
Test
expected value
(200–240 V CSA or 230 V Ce)
19
VACR (rectified AC line
voltage)
1.95 V at 230 line voltage
21
VBUS (DC bus voltage)
2.28 VDC at 385 VBUS
18
(200–240 and 230 V only)
IPFC (input current)
< 0.1 VDC
20
IFB (output current)
< 0.1 VDC
22
ITF (transfer current)
< 0.1 VDC
25
3.3 VDC
3.3 VDC ±5%
24
5 VDC
5 VDC ±5%
12
24 V sense pin
2.2 VDC
16
Start signal
3.2 VDC closed