Controls and indicators

The Powermax45 has an ON/OFF switch, an amperage adjustment knob, a pressure regulator knob, a mode switch,

4 indicator LEDs, and a gas pressure LED, which are described below.

front controls and leds

Temperature led (yellow)
When illuminated, this LED indicates that the power supply temperature is outside the acceptable range.

Torch cap sensor led (yellow)

When illuminated, this LED indicates that the consumables are loose, improperly installed, or missing.

For information on the possible fault conditions, refer to the Troubleshooting guide topic in the

Troubleshooting and System Tests section. If this LED illuminates, the power must be turned OFF, the

consumables installed properly, and the system turned ON again to reset it.

fault led (yellow)
When illuminated, this LED indicates that there is a fault with the power supply. Some fault conditions

will cause one or more of the LEDs to blink. For information on what these fault conditions are and how

to correct them, refer to the Troubleshooting guide topic in the Troubleshooting and System Tests

section.

AC

Power oN led (green)
When illuminated, this LED indicates that the power switch has been set to I (ON) and that the safety

interlocks are satisfied.

gas pressure led and pressure bar (yellow/green)
When the LED indicator in the pressure bar illuminates green and is centered in the vertical bar, the gas

pressure is set correctly for the mode of cutting selected with the mode switch. If the pressure is too

high for the selected mode, the indicator in the pressure bar will be above the mid-point of the bar. If

it is too low, the indicator will be below the mid-point. At the highest and lowest points on the bar, the

indicator will illuminate yellow.
If the indicator is at the lowest part of the bar and is flashing, then the gas pressure is less than the

minimum required pressure.