Troubleshooting guide, Power led faults – Hypertherm Powermax30 AIR Service Manual User Manual
Page 63

Powermax30 AIR Service Manual 808850
63
5 – Troubleshooting and System Tests
Troubleshooting guide
This guide provides the most common causes and solutions.
Before troubleshooting, study the
Powermax30 AIR schematic on page 222 and understand the Theory of operation
Before purchasing any major replacement component, verify the problem with Hypertherm Technical Service or the
nearest Hypertherm repair facility listed in the front of this manual.
System tests on page 73 for detailed test procedures.
Power LED faults
The ON/OFF power switch is set to ON (I),
but the power ON LED does not illuminate.
Possible causes
Possible solutions
The system has no incoming voltage or an
improper incoming voltage.
The power cord, power switch, or power
board is faulty.
Make sure the electrical power is connected
to an appropriately sized circuit.
Make sure the system did not trip the circuit
breaker.
Perform
Test 1 – voltage input on page 78.
The power ON LED illuminates, but no fault LEDs illuminate, and no gas
flows when you pull the torch trigger.
Possible causes
Possible solutions
The start signal is not reaching the control
board due to:
Damaged torch or torch lead
Faulty power board
OR
Faulty control board
Inspect the torch and torch lead, and
replace if necessary.
Make sure the control board start LED
illuminates when you pull the torch trigger. If
it does not, perform