Requirements for grounding, Power cord considerations, Csa power cords and plugs – Hypertherm Powermax30 AIR Service Manual User Manual
Page 29
Powermax30 AIR Service Manual 808850
29
2 – Power Supply Setup
Requirements for grounding
Properly ground the system as follows to ensure personal safety and proper operation, and to reduce electromagnetic
interference (EMI):
The system must be grounded through the power cord according to national and local electrical codes.
Single-phase service must be of the three-wire type with a green (CSA) or green/yellow (CE) wire for the protective
earth ground and must comply with national and local requirements. Do not use a two-wire service.
Refer to the
Safety and Compliance Manual (80669C) for more information.
Power cord considerations
This system ships with a CSA or CE power cord configuration. See
Exterior, rear on page 203 for part number
information.
CSA power cords and plugs
CSA configurations include the following plug and adapters.
The power cord is equipped with a NEMA twist
lock-style plug (NEMA L6-20P) appropriate for use on
a 240 V / 20 A circuit with a NEMA twist lock-style
outlet.
To operate the system on a lower amperage circuit,
attach the female end of the 120 V / 15 A
(NEMA 5-15P) plug adapter to the power supply’s
NEMA twist lock-style plug.
Do not set the amperage adjustment knob above
20 A, or you may trip the circuit breaker. See
Step 3 – Adjust the output current on page 45.
To operate the system on a 240 V / 20 A circuit, attach
the female end of the 240 V / 20 A (NEMA 6-50P)
plug to the power supply’s NEMA twist lock-style plug.