beautypg.com

Operation 3-36 duramax retrofit torch – Hypertherm HRT User Manual

Page 72

background image

OPERATION

3-36

Duramax Retrofit Torch

Operator Manual

45 A Unshielded
Aluminum

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

1

1.5

3.8

250

0.0

7400

126

11000

121

2

0.1

4400

127

9200

123

3

0.2

2800

129

6250

125

4

0.4

2100

132

4700

126

6

0.5

1050

135

2250

127

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

1/32

0.06

0.15

250

0.0

325

126

450

121

1/16

0.1

200

126

400

122

3/32

0.2

150

127

328

124

1/8

0.4

100

130

224

125

1/4

0.5

36

136

72

127

This manual is related to the following products: