beautypg.com

Operation duramax retrofit torch – Hypertherm HRT User Manual

Page 51

background image

OPERATION

Duramax Retrofit Torch

Operator Manual

3-15

65 A Shielded
Stainless Steel

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

2

1.5

3.8

250

0.1

8100

125

10000

121

3

0.2

6700

125

8260

123

4

0.5

5200

125

6150

124

6

2450

126

2850

126

8

0.7

1500

129

1860

129

10

4.5

300

960

132

1250

132

12

1.2

750

135

920

134

16

Edge Start

500

139

500

139

20

300

143

370

143

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

16 GA

0.06

0.15

250

0.1

345

124

426

121

10 GA

240

125

296

123

3/16

0.2

155

126

168

125

1/4

0.5

80

126

96

126

3/8

0.7

40

131

52

131

1/2

0.18

300

1.2

26

136

32

135

5/8

Edge Start

20

139

20

139

3/4

14

142

15

142

This manual is related to the following products: