Operation duramax retrofit torch – Hypertherm HRT User Manual
Page 71
![background image](https://www.manualsdir.com/files/789581/content/doc071.png)
OPERATION
Duramax Retrofit Torch
Operator Manual
3-35
45 A Unshielded
Stainless Steel
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
mm/min
Volts
mm/min
Volts
0.5
1.5
3.8
250
0.0
9000
121
12500
119
1
9000
121
10800
119
1.5
0.1
9000
121
10200
120
2
0.3
6000
122
9600
120
3
0.4
3250
123
4750
120
4
1900
128
3000
122
6
0.5
700
130
1450
124
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
in
in
in
%
seconds
ipm
Volts
ipm
Volts
26 GA
0.02
0.08
400
0.0
350
120
500
119
22 GA
350
120
450
119
18 GA
0.1
350
118
400
119
16 GA
350
121
400
120
14 GA
0.06
0.15
250
0.2
300
122
400
120
12 GA
0.4
150
121
224
120
10 GA
100
125
140
121
3/16
0.5
42
131
88
123
1/4
0.6
25
130
48
124