beautypg.com

Operation 3-10 duramax retrofit torch – Hypertherm HRT User Manual

Page 46

background image

OPERATION

3-10

Duramax Retrofit Torch

Operator Manual

85 A Shielded
Aluminum

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

3

1.5

3.8

250

0.1

8000

122

9400

121

4

0.2

6500

123

8000

123

6

0.5

3800

126

4900

126

8

2650

130

3470

129

10

4.5

300

1920

132

2500

131

12

0.7

1450

134

1930

133

16

1.0

950

139

1200

137

20

Edge Start

600

143

880

141

25

380

146

540

144

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

1/8

0.06

0.15

250

0.2

300

122

360

121

1/4

0.5

130

127

172

127

3/8

80

132

104

131

1/2

0.18

300

50

135

68

133

5/8

1.0

38

139

48

137

3/4

Edge Start

25

142

37

140

7/8

20

144

29

142

1

14

146

20

144