Operation 3-8 duramax retrofit torch – Hypertherm HRT User Manual
Page 44
OPERATION
3-8
Duramax Retrofit Torch
Operator Manual
85 A Shielded
Mild Steel
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
mm/min
Volts
mm/min
Volts
3
1.5
3.8
250
0.1
6800
122
9200
120
4
0.2
5650
122
7300
122
6
0.5
3600
123
4400
125
8
2500
125
3100
127
10
1680
127
2070
128
12
4.5
300
0.7
1280
130
1600
130
16
1.0
870
134
930
133
20
6.0
400
1.5
570
137
680
136
25
Edge Start
350
142
450
141
30
200
146
300
144
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
in
in
in
%
seconds
ipm
Volts
ipm
Volts
10 GA
0.06
0.15
250
0.0
250
122
336
121
3/16
0.2
185
123
220
123
1/4
0.5
130
123
160
126
3/8
70
126
86
127
1/2
0.18
300
45
131
56
131
5/8
1.0
35
134
37
133
3/4
0.24
400
1.5
24
136
29
135
7/8
Edge Start
19
139
22
138
1
13
142
17
141
1‑1/8
9
145
13
143
1‑1/4
7
148
10
146