Operator Manual

85 A Shielded
Mild Steel

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

3

1.5

3.8

250

0.1

6800

122

9200

120

4

0.2

5650

122

7300

122

6

0.5

3600

123

4400

125

8

2500

125

3100

127

10

1680

127

2070

128

12

4.5

300

0.7

1280

130

1600

130

16

1.0

870

134

930

133

20

6.0

400

1.5

570

137

680

136

25

Edge Start

350

142

450

141

30

200

146

300

144

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

10 GA

0.06

0.15

250

0.0

250

122

336

121

3/16

0.2

185

123

220

123

1/4

0.5

130

123

160

126

3/8

70

126

86

127

1/2

0.18

300

45

131

56

131

5/8

1.0

35

134

37

133

3/4

0.24

400

1.5

24

136

29

135

7/8

Edge Start

19

139

22

138

1

13

142

17

141

1‑1/8

9

145

13

143

1‑1/4

7

148

10

146