OPERATION

Duramax Retrofit Torch

Operator Manual

3-31

65 A Unshielded
Stainless Steel

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

2

2.0

5.0

250

0.1

7950

117

10300

116

3

0.2

6600

118

8500

117

4

0.5

5050

119

6500

119

6

2300

121

3070

121

8

0.7

1400

123

1900

122

10

6.0

300

0.7

920

126

1250

123

12

Edge Start

710

130

925

127

16

430

135

500

133

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

16 GA

0.08

0.20

250

0.1

340

116

437

115

10 GA

235

118

304

118

3/16

0.2

150

120

194

120

1/4

0.5

75

121

100

121

3/8

0.24

300

0.7

38

125

52

122

1/2

Edge Start

25

132

32

129

5/8

17

135

20

133