Operation 3-18 duramax retrofit torch – Hypertherm HRT User Manual
Page 54
OPERATION
3-18
Duramax Retrofit Torch
Operator Manual
Note:
Torch‑to‑work dis tance for the following cut chart is 1/16 in (1.5 mm) for all cuts.
Mild steel
Arc current Arc voltage Pierce
delay
Material thickness
Recommended
cut speed
Maximum cut speed
in
mm
ipm
mm/min
ipm
mm/min
60
134
0
16 Ga
1.5
502
12751
627
15926
134
10 Ga
3.4
211
5359
264
6706
138
0.25
1/4
6.4
86
2184
132
3353
141
0.75
3/8
9.5
41
1041
63
1600
141
1.50
1/2
12.7
27
686
42
1067
147
5/8
15.9
20
512
31
787
153
3/4
19.0
14
363
22
559
Stainless steel
Arc current Arc voltage Pierce
delay
Material thickness
Recommended
cut speed
Maximum cut speed
in
mm
ipm
mm/min
ipm
mm/min
60
134
0
16 Ga
1.5
406
10312
625
15875
136
0.25
10 Ga
3.4
159
4039
244
6198
139
0.50
1/4
6.4
72
1829
110
2794
145
0.75
3/8
9.5
34
864
53
1346
146
2.00
1/2
12.7
23
584
35
889
149
5/8
15.9
17
429
26
660
154
3/4
19.0
12
297
18
457
Aluminum
Arc current Arc voltage Pierce
delay
Material thickness
Recommended
cut speed
Maximum cut speed
in
mm
ipm
mm/min
ipm
mm/min
60
135
0
1/16
1.6
433
10995
666
16916
138
0.25
1/8
3.2
260
6604
400
10160
141
1/4
6.4
94
2388
145
3683
146
0.75
3/8
9.5
48
1219
74
1880
149
1.50
1/2
12.7
30
762
51
1295
153
5/8
15.9
21
545
33
838