Operation duramax retrofit torch – Hypertherm HRT User Manual
Page 57
![background image](https://www.manualsdir.com/files/789581/content/doc057.png)
OPERATION
Duramax Retrofit Torch
Operator Manual
3-21
45 A Shielded
Stainless Steel
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
mm/min
Volts
mm/min
Volts
0.5
1.5
3.8
250
0.0
9000
130
12500
129
1
9000
130
10800
130
1.5
0.1
9000
130
10200
130
2
0.3
6000
132
8660
131
3
0.4
3100
132
4400
132
4
2000
134
2600
134
6
0.5
900
140
1020
139
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
in
in
in
%
seconds
ipm
Volts
ipm
Volts
26 GA
0.02
0.08
400
0.0
350
130
500
129
22 GA
350
130
450
129
18 GA
0.1
350
130
400
130
16 GA
350
130
400
130
14 GA
0.06
0.15
250
0.2
250
132
360
131
12 GA
0.4
140
132
206
131
10 GA
100
133
134
134
3/16
0.5
52
135
58
135
1/4
0.6
30
141
35
140