Page 13

Operator's Guide
Byte(s) Bit(s)
Description
Mapping
2
1
Dead sensor channel
Not used
2
Zeroed data
Not used
3
Clipped
Not used
4
Calibration underway
Set when calibration is in
progress on associated
component
3
1
Equipment housing open Configurable tamper monitor
2
Digitiser open
Configurable tamper monitor
3
Vault door opened
Configurable tamper monitor
4
Authentication seal
broken
Configurable tamper monitor
5
Equipment moved
Configurable tamper monitor
6–8
Future use
Configurable tamper monitors
4
1
Clock diff. too large
Set if clock difference
≥±1000µs (configurable)
2
GPS receiver off
Set if ADC module reports no
communication from GPS, or
GPS power is off
3
GPS receiver unlocked
Set if ADC module reports
clock is not phase locked to
GPS PPS signal
4
Analog input shorted
Not used
5
Calibration loop back
Not used
6–8
Future use
Not used
5
1
Main power failure
Configurable; set if voltage of
chosen line drops below
specified value
2
Backup power unstable
Configurable; set if voltage of
chosen line drops below
specified value (independent
from main power failure bit)
3–8
Future use
Not used
6
1–8
Undefined
Configurable; 8-bit voltage,
temperature, power or
current reading #1
7
1–8
Undefined
Configurable; 8-bit voltage,
temperature, power or
June 2010