beautypg.com

Groth 3000 Series User Manual

Page 8

background image

5

OPERATION

PRESSURE SETTING

The regulator may be set at the factory or on the tank
or vessel when initially introducing blanketing gas.
A pressure gauge (or manometer) is required to show
the tank pressure.

Set pressure is adjusted by removing the valve cap
[1] and rotating the adjusting screw [2]. Back off the
jam nut [3] and turn the screw clockwise (tighten) to
increase set pressure. The Model 3000 Regulator
covers a range of set pressures from 2" WC to 2.0
PSI, using (7) different springs.

The model 3010 is required for set pressures from
1/2" WC to 2" WC, and model 3020 from 2.0 PSI to
10.0 PSI. In some cases, different actuator
components are also required, either to reduce the
weight for low settings or to withstand the forces due
to higher pressure. (See. Tables 3, 4 and 5).

The set pressure range with the original spring is
stamped on the valve nameplate. The regulator will
not function properly if the setting is not within this
range. If higher or lower settings are required, the
necessary components can be obtained from Groth
Corporation. They must be installed according to
instruction in the maintenance section of this manual.
Tables 3, 4 and 5 show standard set pressure ranges.

TABLE 3

SPRING TABLE

MODEL 3000

TANK BLANKETING REGULATOR

MEDIUM PRESSURE RANGE

SET PRESSURE RANGE: 2" WC - 2.0 PSIG

Spring

Range

Min.

Setting

Max.

Setting

Spring

P/N

Support

Plate

Back-up

Plate

Tank

MAWP

1

2.0"
WC

3.4"
WC

84209001

(Yellow)

83602015 83601005

4

PSI

2

3.4"
WC

6.3"
WC

84209002

(Green)

83602015 83601005

4

PSI

3

6.3"
WC

10.9"

WC

84209003

(Pink)

83602015

83601005

4

PSI

4

11.0"

WC

18.5"

WC

84209004

(Blue)

83602025

83601025

25

PSI

5

18.6"

WC

27.7"

WC

84209005

(White)

83602025

83601025

25

PSI

6

1.00

PSI

1.37 PSI

84209006

(Gray)

83602025

83601025

25

PSI

7

1.38

PSI

2.0

PSI

84209007

(Black)

83602025 83601035

25

PSI


TABLE 4

SPRING TABLE

MODEL 3010

TANK BLANKETING REGULATOR

LOW PRESSURE RANGE

SET PRESSURE RANGE: 0.5" WC - 2.0" WC

Spring

Range

Min.

Settin

g

Max.

Setting

Spring

P/N

Support

Plate

Back-up

Plate

Tank

MAWP

1


0.5"
WC

0.6"
WC

84209008

(Red)

83602035 83601005

10"

WC

2


0.7"
WC

1.0"
WC

84209001

(Yellow)

83602035 83601005

10"

WC

3


1.1"
WC

2.0"
WC

84209002

(Green)

83602005 83601015

10"

WC




TABLE 5

SPRING TABLE

MODEL 3020

TANK BLANKETING REGULATOR

HIGH PRESSURE RANGE

SET PRESSURE RANGE: 1.0 - 10.0 PSIG

Spring

Range

Min.

Setting

Max.

Setting

Spring

P/N

Support

Plate

Back-up

Plate

Tank

MAWP

1


1.0

PSI

1.80

PSI

84209002

(Green)

84829005 N/A

150
PSI

2


1.81

PSI

3.07

PSI

84209003

(Pink)

84829005 N/A

150
PSI

3


3.08

PSI

5.21

PSI

84209004

(Blue)

84829005 N/A

150
PSI

4


5.22

PSI

10.0 PSI

84209005

(White)

84829005 N/A

150
PSI




WARNING

The recommended set pressure range of the regulator
spring is stamped on the nameplate. Never adjust a
spring for a set pressure above its upper design limit
as specified in Tables 3, 4 and 5. Exceeding the spring
rang may compress the spring to its solid height. If
this happens the regulator may not close and the tank
could be over-pressured if the relief valve capacity is
less than supply gas flow rate.