Troubleshooting, Heater does not operate – Greenheck DG / DGX with Pilot Ignition (463555 IOM) (Pre-2008) User Manual
Page 36

36
Troubleshooting
Troubleshooting
No
Check for proper pilot pressure.
(Direct Gas Start-Up #2)
Check inlet gas pressure.
(Direct Gas Start Up Step #1)
Note: The minimum and maximum gas pressures for your unit are
shown on the direct gas label. Reference start-up procedure #1
Gas pressure between the min
and max shown on the direct gas
label?
Correct gas pressure
(Reference Direct Gas Start-Up Step #1)
Proper spark?
Crossed flame and spark wires
(Uncross wires and reconnect)
Incorrect spark plug gap
(Set spark plug gap to 0.062 in.)
Defective spark plug
(Replace spark plug)
Pressure drop across the
burner between 0.625 and
0.675 in. wc?
Adjust burner baffles
(Reference Direct Gas Start-Up Step #4)
Check for proper airflow
(Direct Gas Start-Up Step #4)
Note: The airflow may satisfy the airflow switch, but may make
lighting the pilot difficult. Adjust the pressure drop across the burner
to 0.625 in. wc shown in Direct Gas Start-Up Step #4.
Air in the gas line?
Purge gas line
(Verify gas at the pilot)
No
No
Yes
No
No
Yes
Yes
Yes
Yes
No
Note: A high pilot pressure will make lighting more difficult. Lower the
pilot pressure in increments until the unit lights. Then set the pilot per
the instruction in Direct Gas Start-Up procedure #2)
Yes
Adjust the pilot pressure
(Reference Direct Gas Start-Up Step #2)
Heater Does Not Operate
Attempts to light but no visible pilot (Visible spark)
Pilot pressure correct?
Yes
With proper airflow, gas pressure and spark,
the unit should light.
If problems remain, consult the factory