Figure 3-8 – Gasboy PLUS FMS User Manual
Page 20

Installing FedEx Islander PLUS FMS
Page 3-10
MDE-5067 FedEx Islander PLUS FMS Installation Manual · March 2013
4
Mechanical dispenser: Note that instead of the solenoid lead tying to the Reset Complete wire;
it now connects directly to Terminal Block for the Gasboy PLUS. Also, note that the Reset
Motor and Submersible Feeds tie together in the junction box of the dispenser (see
).
Figure 3-8: Wiring Diagram - Mechanical Dispenser
Note: Reset Complete is the in-use line, this jumpers to line and the load line, which comes
back and run the solenoid valves. Pulse wires are polarized.