Description
The ALC Remote Module, included in the GTC 12395-001 ALC Control Kit, is housed in a separate 
enclosure in the logical subzone to be monitored. 
The location of the mounting holes on the 4.0 
 4.0-inch board are shown in Figure 2 below.
Figure 2. Mounting Dimensions for the ALC Remote Module PCBA
The dummy speaker or dynamic mic must be positioned close by to accurately sample the ambient noise 
in the area. The remote is line-powered by the ALC Control Module, so an additional power source is 
unnecessary. The wire line to the master must be of sufficient size to prevent significant resistance losses 
to the phantom dc power. See the wire-size chart below. 
Guideline: Total line resistance including both conductors must not exceed 20 ohms (10 ohm/wire) 
Table 5. Wire Size Chart
Wire-run, Feet from 
Master to Remote 
Recommended 
Minimum Wire Size 
1000
No. 20 AWG
2000
No. 16 AWG
3000
No. 14 AWG
- 69389-010 NOVA PA/GA Systems S.M.A.R.T. Modules 12399-001 NOVA PA/GA Systems S.M.A.R.T. Modules 69403-101 NOVA PA/GA Systems S.M.A.R.T. Modules 13317-002 NOVA PA/GA Systems S.M.A.R.T. Modules 69389-020 NOVA PA/GA Systems S.M.A.R.T. Modules 12395-001 NOVA PA/GA Systems S.M.A.R.T. Modules 13317-001 NOVA PA/GA Systems S.M.A.R.T. Modules 12604-014 NOVA PA/GA Systems S.M.A.R.T. Modules
 