Status/Message Meaning
Suggested
Action
FAULT
LED is
illuminated.
1. No data
communication.
• Verify cable integrity from API to all associated
access panels.
• Call for service.
2. A component failure
has occurred.
• Replace the API card.
• Call for service.
3. MCU configuration
is not correct.
• Verify the proper MCU configuration as listed in
system manual.
• Call for service.
No audio on a
page resource.
1. The audio path is
impaired.
• Verify the API card is properly seated in the card
rack.
• Verify external equipment connected properly.
• Call for service.
2. A component failure
has occurred.
• Replace the API card.
• Call for service.
3. Problem with access
panel microphone or
pre-amp section.
• Replace access panel.
• Call for service.
Audio low on
page line
1. The volume levels at
the access panels are
improperly set.
• Increase the volume of the access panels in the
affected area (via system configuration).
• Call for service.
2. A component failure
has occurred.
• Replace the API card.
• Call for service.
3. Problem with access
panel microphone or
pre-amp section.
• Replace access panel.
• Call for service.
No audio on a
party line
1. The audio path is
impaired
• Verify the API card is properly seated in the card
rack.
• Verify external equipment connected properly.
• Call for service.
2. A component failure
has occurred
• Replace the API card.
• Call for service.
3. Problem with access
panel microphone or
pre-amp section.
• Replace access panel.
• Call for service.
Audio low on a
party line
1. A component failure
has occurred.
• Replace the API card.
• Call for service.
2. Problem with access
panel microphone or
pre-amp section.
• Replace access panel with spare.
• Call for service.