VoIP Telephone Wiring
Refer to Figure 3 and Figure 4.
1. The Ethernet cable must enter the stanchion through one of the holes on the right hand side of the
unit when viewed from the front.
2. The ac power line must enter the stanchion through one of the holes on the left side of the unit when
viewed from the front. Secure the wires to the terminal block as noted on the label. See Figure 3.
3. Install the violet (V) and orange (O) beacon wires from inside the stanchion to P10 on the VoIP
Carrier PCBA as shown in Figure 4.
4. If utilizing PoE, connect the power to the system as indicated in the PoE manual. If utilizing local
power, connect the positive conductor to the (+) terminal and the negative conductor to the (−)
terminal of P5 on the telephone (customer-supplied wiring). Connect the positive conductor to the
(+) terminal (3) and the negative conductor to the (−) terminal (4) of the TB1 located in the top
section of the stanchion. See Figure 5 and Figure 6 for 24 V dc wiring as well as the appropriate
telephone installation manuals.
5. Plug the Ethernet cable into the VoIP Circuit PCBA as shown in Figure 4.