beautypg.com

Installation guidelines, Mounting – GAI-Tronics 239WM-001 Slim Wall-Mount Stanchions User Manual

Page 2

background image

Pub. 42004-476A

Model 239WM-001 & 239WM-002 Slim Wall-Mount Stanchions

Page

2 of 9

e:\standard ioms - current release\42004 instr. manuals\42004-476a.doc
08/14

Installation Guidelines

 GAI-Tronics’ Emergency Telephones are not designed to be installed in parallel or to be “party-

lined.” Any such installation can cause programming difficulties, premature disconnection of calls,
or stations that may not respond when activated. GAI-Tronics highly recommends that one telephone
line (PBX extension or CO line) be allocated for each unit.

 GAI-Tronics highly recommends that a telephone line surge suppressor be installed to guard against

lightning strikes. Please consult Distributor Sales at 800-838-9313 if further information is required.

 Sealed fittings should be installed at all cable entry points to prevent liquids from entering the unit.
 Secure the front cover using the screws and washers provided. Torque the screws to 10–12 in-lbs.

(1.13–1.36 n-m).

 This permanently connected apparatus must have a 15-amp circuit breaker incorporated in the

electrical installation of the building.

Mounting

NOTE

GAI-Tronics flush-mount telephones are equipped with a metal back box that is

not required and should be removed prior to installing the telephone in the stanchion.

1. Cables can enter the stanchion either through access holes in the back or the bottom of the unit. Hole

caps are provided to seal the holes that are not used. The Model 239WM-00x is provided with two
hole caps installed in the bottom of the enclosure. If entry is from the back of the unit, install two
gaskets (provided) to seal around the holes. If conduit entrance is desired into the bottom of the
unit, remove the hole caps from the bottom two holes and install them in the two holes located on the
back of the enclosure.

2. Mount the enclosure on a flat wall surface using the four 5/16-inch (0.312) diameter holes as shown

in Figure 1. Four rubber washers are provided to ensure weather-tight sealing.
N

OTE

: Mounting hardware is not provided.