beautypg.com

Digital inputs – GAI-Tronics 10959-201 and 10959-203 Wall-mount Audio Messenger Interface User Manual

Page 9

background image

Pub. 42004-403F

M

ODEL

10959-201

AND

-203

W

ALL

-M

OUNT

A

UDIO

M

ESSENGER

I

NTERFACES

P

AGE

7 of 20

f:\standard ioms - current release\42004 instr. manuals\42004-403f.doc
11/13

Table 2. Digital Output Assignment

Termination
PCBA Label

Internal Terminal
Pin-Out

Function or ACT
Description

GND

TB1-1

Ground or dc common

1 TB1-2

Output

1

2 TB1-3

Output

2

3 TB1-4

Output

3

4 TB1-5

Output

4

5 TB1-6

Output

5

6 TB1-7

Output

6

7 TB1-8

Output

7

8 TB1-9

Output

8

GND

TB1-10

Ground or dc common

Digital Inputs

Terminal block TB2, labeled DIGITAL

INPUTS

is located on the termination PCBA. It provides eight

digital common ground inputs. The input contacts may be any combination of momentary (pulsed)
switches and maintained (latched) switches. They can be either normally open or closed dry contacts
rated at 5 mA or better. The ground or dc common terminals for the controlled circuits must be tied to
GND on the terminal block.

For the inputs to operate reliably, the cable loop resistance connecting the relay/switch contact closures
cannot exceed 200 ohms.

Table 3. Digital Input Assignment

Termination
PCBA Label

Internal Terminal
Pin-Out


Function or ACT Description

GND

TB2-1

Ground or dc common

1 TB2-2

Input

1

2 TB2-3

Input

2

3 TB2-4

Input

3

4 TB2-5

Input

4

5 TB2-6

Input

5

6 TB2-7

Input

6

7 TB2-8

Input

7

8 TB2-9

Input

8

GND

TB2-10

Ground or dc common