Table 2. Digital Output Assignment
Termination
PCBA Label
Internal Terminal
Pin-Out
Function or ACT
Description
GND
TB1-1
Ground or dc common
1 TB1-2
Output
1
2 TB1-3
Output
2
3 TB1-4
Output
3
4 TB1-5
Output
4
5 TB1-6
Output
5
6 TB1-7
Output
6
7 TB1-8
Output
7
8 TB1-9
Output
8
GND
TB1-10
Ground or dc common
Digital Inputs
Terminal block TB2, labeled DIGITAL
INPUTS
is located on the termination PCBA. It provides eight
digital common ground inputs. The input contacts may be any combination of momentary (pulsed)
switches and maintained (latched) switches. They can be either normally open or closed dry contacts
rated at 5 mA or better. The ground or dc common terminals for the controlled circuits must be tied to
GND on the terminal block.
For the inputs to operate reliably, the cable loop resistance connecting the relay/switch contact closures
cannot exceed 200 ohms.
Table 3. Digital Input Assignment
Termination
PCBA Label
Internal Terminal
Pin-Out
Function or ACT Description
GND
TB2-1
Ground or dc common
1 TB2-2
Input
1
2 TB2-3
Input
2
3 TB2-4
Input
3
4 TB2-5
Input
4
5 TB2-6
Input
5
6 TB2-7
Input
6
7 TB2-8
Input
7
8 TB2-9
Input
8
GND
TB2-10
Ground or dc common