M
ODEL
10959-201
AND
-203
W
ALL
-M
OUNT
A
UDIO
M
ESSENGER
I
NTERFACES
P
AGE
9 of 20
f:\standard ioms - current release\42004 instr. manuals\42004-403f.doc
11/13
Ethernet
The Ethernet connector, plug J1, is located on the termination PCBA, and is reserved for future
implementation.
Power
The terminal block TB6, labeled CLASS
2
12
–24
VDC
is located on the termination PCBA. It provides
power connection for the AMI.
Table 6. Power Assignment
Metalwork
Label
Internal Terminal
Pin-Out
Function or ACT Description
+
TB6-1
Positive terminal of external power supply
(Black wire with white stripe from power supply)
−
TB6-2
Negative terminal of external power supply
(Solid black wire from power supply)
GND TB6-3
Frame
ground
Optional PBX Connection
The PBX connector is located on the optional telephone interface PCBA, and provides connection to a
standard PBX analog station port. It may be used as a plug-in connection or with the terminal screws
designated for tip (green) and ring (red).
Page/Party
®
The connector P1 is located on the Page/Party
®
Interface PCBA and provides connection to a Page/Party
®
system.
Table 7. Page/Party
®
Assignment
Metalwork
Label
Internal Terminal
Pin-Out
Function or ACT Description
Party L1
P1-1
The 33-ohm line interface to GAI-Tronics party line.
Internal 33-ohm termination.
Party L2
P1-2
Page L1
P1-3
The 33-ohm line interface to GAI-Tronics page line.
External 33-ohm termination required.
Page L2
P1-4
N
OTE
: Pin 1 on this connector is on the right side.