Spc-15 specifica tions, Power product group – FSR SPC-15 User Manual
Page 6

POWER PRODUCT GROUP
Phone: 973-785-4347 Fax: 973-785-3318
W
eb: www
.fsrinc.com E-Mail: [email protected]
FSR
SPC-15 SPECIFICA
TIONS
AC INPUT
120V
AC, 60 Hz, 12
Amps max.
AC INPUT
:
Full line conditioning and RFI suppression
AC SWITCHING:
Solid state zero crossing (no relays that bounce,
arc,
and
pit)
AC OUTLETS:
Sur
ge suppression on all outlets
AC OUTLETS:
T
otal of
fi
ve outlets, two (one on the front panel and one on
the rear panel) are active, the other three are switched on/of
f in sequence.
T
otal output curr
ent must not exceed 12
Amps. Each
AC outlet is rated at 12
Amps but r
emember
that the total curr
ent out of the SPC-15 must not exceed 12
Amps.
SURGE PROTECTION:
Spike protection modes: Line to neutral, neutral to
ground,line to ground Spike protection voltage:
Max clamping voltage 340V
peak, L-N, N-G, L-G
Response
time:
1
nanosecond
Maximum sur
ge current: >100,000
AMPS (8x20
usec
pulse)
Maximum spike ener
gy: >1000 joules
Noise attenuation: Dif
ferential 13 dB @ 150 kHz
increasing to 45 dB @ 30 Mhz
Common mode: 15 dB @ 150 kHz, increasing to
>45 dB @ 30 Mhz
SWITCHING DELA
Y
: 1 to 50 seconds adjustable on the rear panel.
This is the delay
from circuit 1 to circuit 2.
A
ll s
u
bse
q
ue
n
t de
la
ys w
il
l b
e one to three seconds, depen-
dent on the adjustment.
Example:
When the SPC-15 power is powered up, via either the front panel power switch or via
remote triggering and you have chosen to set the delay to 20 secs:
The SPC-15 “circuit 1” turns on within 1 sec.
Then, the SPC-15 “circuit 2” turns on in 20 secs.
Then, the SPC-15 “circuit 3” turns on in 22 secs.
Then, the
fi
rst SPC-15X expansion module turns on in 24 secs.
Then, the second SPC-15X expansion module turns on in 26 secs. and so on for
additional SPC-15X modules.
When the SPC-15 power is powered down, via either the front panel power switch or
via remote triggering, all delays happen in reverse:
The last SPC- 15X expansion module turns of
f
fi
rst.
Additional SPC-15X expan-
sion modules will continue to turn of
f in sequence at 2 second intervals.
Then, 2 secs later
, after all the SPC-15X expansion modules have sequenced of
f,
the SPC-15 “circuit 3” turns of
f
Then, 20 seconds later
, the SPC-15 “circuit 2” turns of
f
Then, within one sec, “circuit 1” turns of
f
REMOTE CONNECT
OR:
Includes all connections for remote control of the unit
(pluggable screw terminal connector)
REMOTE CONTROL:
Momentary or maintained closure will operate
this
equipment.
A
lamp feedback signal (voltage)
is also pro-
vided.
EXP
ANSION CONNECT
OR:
Feeds the
fi
rst expansion unit if used
(data connector
6 wide RJ 12) wire this connector straight through.
NOTE
THIS IS NOT
T
O
BE USED
AS
A
TELECOM INPUT
. DO NOT
PLUG
A
TELPHONE INT
O
THIS CONNECT
OR
SIZE:
19” wide, 1.75”high and 8.5” deep
WEIGHT
:
14 lbs.