4 operation, 1 product id settings, 2 initialization – FSR DV-HMSW-88 8x8 MATRIX User Manual
Page 9

9
4 OPERATION
4.1 Product ID settings
(1) When using the Configure key on front panel
Push configure the (Config) key on front panel -> push the Select (Select) key until the LCD shows the number you
want (Rotating number)
(2) When using the Dip switch on the back panel
Dip switch sets address for each matrix if many matrixes are used.
Dip switch sets a binary value.
Ex)
Product ID = 01 (00000001b) -- 1 ON, 2 OFF, 3 OFF, 4 OFF, 5 OFF, 6 OFF, 7 OFF, 8 OFF,
Product ID = 10 (00001010b) -- 1 OFF, 2 ON, 3 OFF, 4 ON, 5 OFF, 6 OFF, 7 OFF, 8 OFF,
Product ID = 23 (00010111b) -- 1 ON, 2 ON, 3 ON, 4 OFF, 5 ON, 6 OFF, 7 OFF, 8 OFF
The product number is the value set on the dip switches of the equipment and can be any value from 1 ~
255. The value “0” is not available.
**The product ID is set number “1” at the time of its delivery (Factory Default).
4.2 Initialization
On initial power on, the preview buttons are displayed with 2 steps as follow.
If each preview button is lit, then the initialization is completed.
(1) Initialization display
Check each input port to see whether EDID is saved in the port
If EDID data is saved, LED of input button is lit for about 4 seconds.
----------- INPUT -----------------
---------- CONTROL -----------
1 2 3 4 5 6
CREATE
PREVIEW ENTER
CANCEL
EDID
CRE
PRE
ENT
CAN
EDI
1 2 3 4 5 6
----------- OUTPUT -----------------
(2) Channel display and input selection
After the initialization, preview button is lit.
----------- INPUT -----------------
---------- CONTROL -----------
1 2 3 4 5 6
CREATE
PREVIEW
ENTER
CANCEL
EDID
1
2
3
4
5
6
7
8
D0 D1 D2 D3 D4 D5 D6 D7
LSB