Troubleshooting – Formax FD 2000IL System User Manual
Page 16
12
TROUBLESHOOTING
TROUBLE
POSSIBLE CAUSE
REMEDY
Control panel lights are
not illuminated.
No power at the wall outlet.
No power to the machine inlet.
No power to the control panel.
Internal electrical failure
Check wall outlet.
Check power cord for frayed/broken
wires.
Press the black breaker reset button
located on the backside of the sealer,
(see page 14, Fig. 14).
Call for service
Sealer does not turn on
when the form enters
the throat of the sealer
transport deck.
Sealer is not turned on
Sealer reset button has not
been pressed after a paper jam
Sealer breaker has popped
Photo eye is not detecting the
form
Check that the sealer is plugged in and
turned to the on position.
Press the “fault reset” button to reset the
sealer
Press the black breaker reset button
located on the backside of the sealer,
(see page 14, Fig. 14).
Wipe sensor with dry cloth.
Call for service.
Forms are misfolding.
Fold plate is not set properly
Fold plates are not inserted
correctly.
Piece of paper or other material
is stuck in the fold plate
Check to make sure the fold stop “bar”
aligns with the correct fold setting on
each fold plate. (See page 8.)
Fold plates may need to be moved up or
down if the fold varies from the standard
fold setting indicators.
Remove and reinstall fold plates. Be
sure they’re properly positioned.
Remove object from the fold plate.
“Cover Open” LED is on. Cover is open
Magnetic switch is broken.
Check that all covers are closed.
Call for service.