20 how to order, 1 positioners, How to order – Flowserve 500+ Series Logix User Manual
Page 61: Ositioners

User Instructions - Logix® 500+ Series Digital Positioners FCD LGENIM0105-10 11/13
flowserve.com
61
20 HOW TO ORDER
20.1 Positioners
Table 27: 500+ Positioner Configurations
Selection
Description
Code Example
Base Model
Logix 500+ Series
5
5
Communications and
Diagnostics
HART; 8-DIP Set-Up with LCD Option; Standard (Basic Functionality)
1, 2
20MD+
20M
D
+
HART; 8-DIP Set-Up with LCD Option; Advanced (With Pressure Sensing)
1, 2
21MD+
HART; 8-DIP Set-Up with LCD Option; Pro (With Full ValveSight Diagnostics)
1
22MD+
Certifications
General Purpose
14
37
Intrinsically Safe, IP66, North America/ATEX/IECEx Ex ia
37
Positioner Configuration
-
Housing
Aluminum - Black Base with White Cover
W
W
Aluminum - Black Base with Yellow Cover
Y
Aluminum - Black Base with Black Cover (Automax)
B
Aluminum - Black Base with Black Cover (Accord)
A
Threaded Connections
Mounting: 5/16" 18 UNC, Pneumatics: 1/4" NPTF, Conduit: 1/2" NPTF, Vents 1/4" NPTF
1
1
Mounting: M8 x 1.25, Pneumatics: 1/4" NPTF, Conduit: M20 x 1.5, Vents 1/4" NPTF
2
Mounting: M8 x 1.25, Pneumatics: G1/4", Conduit: M20 x 1.5, Vents G1/4"
3
Feedback Shaft
D - 316 Stainless Steel Shaft (Valtek Standard)
D
D
NAMUR - 316 Stainless Steel Shaft (VDI/VDE 3845)
R
Action
Three-way (Single-Acting), Poppet Style Relay
1
1
Three-way (Single-Acting), Spool Style Relay
2
Four-way (Double-Acting), Spool Style Relay
3
Position Indicator
No Indicator
0
F
Flat Indicator
F
Domed Indicator
D
Special Options
No special options
0
0
Chinese Configuration
6
1
Optional Mechanical Add-Ins
-
Manifold
No Manifold
00
GM
Gauge Manifold - Aluminum (required for gauges)
GM
Pressure Gauges
No Gauges
0
1
Nickel Plated with Brass Internals, psi (bar/kPa)
1
Nickel Plated with Brass Internals. psi (kg/cm2 )
2
SS with SS Internals. psi (bar/kPa)
3
SS with SS Internals. psi (kg/cm2 )
4
UCC Press Test Plug, 1/8" NPT
A
Valve, Tank, Schrader 645A
B
Optional Electronic Add-Ins
-
Display
No LCD
0
1
LCD
6
1
Auxiliary Card Slot 1
Slot 1 - No Card
0
1
Slot 1 - Multi-Function Card
3,
1
Auxiliary Card Slot 2
Slot 2 - No Card
0
0
Slot 2 - Multi-Function Card
3,
1
Limit Switches
or
Remote Mount
No Switches
0
3
Mechanical Limit Switch
4
1
Reed Switch
2
Namur V3 type proximity switch, P+F NJ2-V3-N
4
3
Slot Type NAMUR Sensor, P+F SJ2 S1N
4
4
Slot Type NAMUR Sensor, P+F SJ2 SN
4
5
Namur V3 type proximity switch, P+F NBB2-V3-E2
4
6
Remote Mount Feedback
5,
7
1
HART 6 standard. Can be configured as HART 5 or HART 7 in the field.
2
Can be upgraded to 521MD+ or 522MD+ in the field.
3
Can be configured as Analog Output, Discrete Output or Discrete Input in the field. Slot 2 available only after
slot 1 is filled.
4
Only available for general purpose (certification option 14).
5
Includes adapter board (installed in the positioner) and the low profile remote mount unit (which may be
shipped separately).
6
Only available with the 520MD+ model.