USER INSTRUCTIONS PolyChem M-SERIES ENGLISH 71569218 07-11
flowserve.com
Page 44 of 60
®
Keep contaminants out of the bearing
housing and bearings. 
6.7.6.2 
Close-coupled PolyChem M-series 
pumps 
 
Figure 6-28: Group A and 1 pumps 
 
 
Figure 6-29: Group B and 2 pumps 
This procedure is necessary only if the
outer magnet assembly [0230] or motor must be 
replaced. 
 
Group A and 1 pumps: 
a) 
Loosen the set screw that attaches the outer 
magnet assembly [0230] to the motor shaft. See 
Figure 6-28. 
b)
Remove the outer magnet assembly [0230] from 
the motor shaft. As a disassembly aide, a 
threaded hole has been provided in the center of 
the outer magnet flange [0231] to enable the 
outer magnet flange to be jacked off of the motor 
shaft. One of the square head jackscrews [6575] 
from the lantern [1340] can be used for this step. 
c)
Remove the fasteners [6570.9] that attach the 
outer magnet flange [0231] to the hub [7200]. 
d)
To remove the motor flange [0231], remove the 
four (4) motor flange/motor fasteners [6570.4]. 
e)
The outer magnet flange [0231] can be 
separated from the outer magnet [0230] by 
removing fasteners [6570.3]. 
 
Group B and 2 pumps: 
a) 
Loosen the fasteners [6570.9] that attaches the 
outer magnet assembly [0230] to the hub [7200]. 
See Figure 6-29. 
b)
To remove the lantern [1340], remove the four 
(4) lantern/motor fasteners [6570.4]. 
c)
Loosen the set screws that attaches the hub 
[6814] to the motor, pull the hub off the shaft. 
d)
The outer magnet flange [0231] can be 
separated from the outer magnet [0230] by 
removing fasteners [6570.3]. 
6.8 Examination of parts
 
Cleaning/inspection 
All parts should be thoroughly cleaned and inspected. 
New anti-friction bearings, O-rings, gaskets and lip 
seals should be used (if so equipped). Any parts that 
show wear or corrosion should be replaced with new 
genuine Flowserve parts. 
 
It is important that only non-flammable,
non-contaminated cleaning fluids are used. These fluids 
must comply with plant safety and environmental 
guidelines. 
 
Critical measurements and tolerances 
To maximize reliability of pumps, it is important that 
certain parameters and dimensions are measured 
and maintained within specified tolerances. It is 
important that all parts be checked. Any parts that do 
not conform to the specifications should be replaced 
with new Flowserve parts. 
 
Parameters that should be checked by users 
Flowserve recommends that the user check the 
condition of the individual pump components 
whenever maintenance is performed. It is described 
in more detail below. 
Jackbolt 
[6575] 
Hub 
[7200] 
Outer Magnet 
Flange [0231] 
Lantern 
[1340]
Hub 
[7200] 
Fastener & Lockwasher
Outer Magnet 
Flange [0231] 