6.7.3
 Drive end removal - without breaking 
process containment 
By following the steps in section 6.7.3.1 or
6.7.3.2, the process fluid is contained and the power 
end can be completely removed. This procedure does 
not preclude the use of personal protective gear. 
Personnel should follow their standard plant safety 
practices. 
 
The magnetic coupling will remain engaged
even after the fasteners that attach the drive end to 
the wet end have been removed. This is due to the 
strong radial and axial forces associated with the 
magnetic coupling. 
7 
Do not attempt to remove the drive end
from the wet end without using the jackbolts. The 
magnetic force can cause severe personal injury. 
 
Be sure to separate the inner and
outer magnet assemblies evenly. Cocking of the two 
can result in serious damage to the magnets and/or 
containment shell. It is best to alternatively give each 
bolt a turn to ensure proper and even separation. 
 
6.7.3.1 
Long-coupled PolyChem M-series 
pumps 
 
Figure 6-11: Group A and 1 pumps 
Figure 6-12: Group B and 2 pumps
a)
Remove coupling guard.
b)
Remove the spacer coupling.
c)
Loosen the cap screw(s) holding the bearing 
housing foot to the baseplate. 
d)
To remove the power end from the wet end, on 
Group A and 1 pumps remove the four (4) 
bearing housing/lantern fasteners [6570.6]. On 
Group B and 2 pumps remove the six (6) bearing 
housing/bearing holder fasteners [6570.8]. 
e)
Screw the two (2) square head jackbolts [6575] 
in the lantern (Group A and 1 pumps) or bearing 
housing (Group B and 2 pumps) through the 
threaded holes until each comes into contact 
with its mating part. (see figure 6-11 and 6-12). 
Continue to screw all jackbolts in evenly to 
detach the wet end from the power end. (Figure 
6-13 and 6-14) 
It may be necessary to move the motor to
complete step e). 
 
f) 
The power end can now be moved to the repair 
shop. 
 
Figure 6-13: Group A and 1 pumps 