Flowserve M-series PolyChem User Manual
Page 40

USER INSTRUCTIONS PolyChem M-SERIES ENGLISH 71569218 07-11
flowserve.com
Page 40 of 60
®
Figure 6-14: Group B and 2 pumps
 
6.7.3.2 
Close-coupled PolyChem M-series 
pumps 
 
Figure 6-15: Group A and 1 pumps 
 
Figure 6-16: Group B and 2 pumps 
 
a) 
Loosen the fasteners (if applicable) holding the 
motor to the baseplate. 
b)
To remove the motor from the wet end, on Group 
A and 1 pumps remove the four (4) motor 
flange/lantern fasteners [6570.6]. On Group B 
and 2 pumps remove the six (6) lantern/bearing 
holder fasteners [6570.8]. 
c)
Screw the two (2) square head jackbolts [6575] 
in the lantern through the threaded holes until 
each comes into contact with its mating part. 
(Figure 6-15 and 6-16) Continue to screw both 
jackbolts evenly to disengage the motor from the 
wet end of the pump. (Figure 6-17 and 6-18) 
d)
The drive end can now be moved to the repair 
shop. 
 
Figure 6-17: Group A and 1 pumps 
 
Figure 6-18: Group B and 2 pumps 
 
 
6.7.4 
Removal of drive end from the wet end
The magnetic coupling will remain engaged
even after the fasteners that attach the drive end to 
the wet end have been removed. This is due to the 
strong radial and axial forces associated with the 
magnetic coupling. 
 
Do not attempt to remove the drive end
from the wet end without using the jackbolts. The 
magnetic force can cause severe personal injury. 
 
Be sure to separate the inner and
outer magnet assemblies evenly. Cocking of the two 
can result in serious damage to the magnets and/or 
containment shell. It is best to alternatively give each 
bolt a turn to ensure proper and even separation. 